你的位置:首頁(yè) > 產(chǎn)品展示 > 輻射防護(hù)|電磁波儀器系列 > 個(gè)人劑量報(bào)警儀 >MD-IIIA個(gè)人劑量?jī)x
產(chǎn)品詳細(xì)頁(yè)MD-IIIA個(gè)人劑量?jī)x
- 產(chǎn)品型號(hào):個(gè)人劑量?jī)x
- 更新時(shí)間:2024-03-17
- 產(chǎn)品介紹:MD-IIIA個(gè)人劑量?jī)x是MD-III系列的款式,是專為*設(shè)計(jì)的。采用了多項(xiàng)技術(shù)保證儀器能在環(huán)境溫度和濕度惡劣的條件下正常工作,具有強(qiáng)的抗電磁干擾能力。可用在核電站、核工廠、大專院校、科研單位、醫(yī)療、環(huán)保、海關(guān)等部門。
- 在線留言
MD-IIIAPersonalDosimeterandDosimetrySystem
MD-IIIA個(gè)人劑量?jī)x適用范圍:
MD-IIIA型X、γ個(gè)人劑量?jī)x是MD-III系列的款式,是專為*設(shè)計(jì)的。
采用了多項(xiàng)技術(shù)保證儀器能在環(huán)境溫度和濕度惡劣的條件下正常工作,具有強(qiáng)的抗電磁干擾能力。
可用在核電站、核工廠、大專院校、科研單位、醫(yī)療、環(huán)保、海關(guān)等部門。
MD-IIIA個(gè)人劑量?jī)x是GM計(jì)數(shù)管為探測(cè)器的多功能輻射劑量實(shí)時(shí)測(cè)量?jī)x器。
設(shè)計(jì)用于佩帶在人體軀干部位測(cè)量個(gè)人劑量當(dāng)量Hp(10),也可用于輻射場(chǎng)調(diào)查和偵測(cè)。
具有紅外數(shù)據(jù)通訊和記錄劑量歷史功能。
MD-IIIA個(gè)人劑量?jī)x技術(shù)指標(biāo):
相對(duì)固有誤差:<±10%(137Cs源,1mSv/h)
劑量率依賴性:<±20%(1mSv/h~500mSv/h)
能量響應(yīng)誤差:<±30%(50keV~1.5MeV)
MD-IIIA個(gè)人劑量?jī)x測(cè)量范圍:
累積個(gè)人劑量當(dāng)量Hp(10):0~9999mSv
當(dāng)時(shí)劑量當(dāng)量率:0.1μSv/h~500mSv/h
記錄個(gè)人劑量歷史:每3分鐘一次連續(xù)記錄8小時(shí)(劑量率≤300mSv/h)
響應(yīng)時(shí)間:0.5秒~30秒´10,根據(jù)劑量率自動(dòng)調(diào)整,(劑量率>6.8mSv/h,0.5秒響應(yīng))
電源:AA1.5V(5號(hào))電池一節(jié)。也可用AA3.6V電池一節(jié)
連續(xù)工作時(shí)間:>400h(1.5V堿性電池)
環(huán)境溫度:-30℃~60℃
環(huán)境濕度:95%±3%(40℃)
尺寸:74´50´20mm
重量:90g
MD - personal dosimeter IIIA scope:
MD - IIIA type X, gamma personal dosimeter MD walkman - III series is the latest style, is designed for army of design.
Adopted many patent technology guarantee instrument in the environmental temperature and humidity can work normally under harsh conditions, with strong anti electromagnetic interference ability.
Can be used in nuclear power plants, nuclear factories, colleges and universities, scientific research units, medical, environmental protection, customs and other departments.
MD - IIIA personal dosimeter is GM counting pipe for the multi-function radiation dose probe real-time measuring instrument.
Designed to wear in human torso measurement personal dose equivalent Hp (10), also can used for radiation field investigation and detection.
With infrared data communication and record dose history function.
MD - IIIA personal dosimeter technical index:
Relative intrinsic error: < + 10% (137Cs source, 1mSv/h)
Dose rate dependence: < + 20% (1mSv/h ? 500mSv/h)
Energy response error: < + 30% (50keV ? 1.5 MeV)
MD - IIIA personal dosimeter measurement range:
Cumulative personal dose equivalent Hp (10) : 0 9999mSv ?
When dose equivalent rate: 0.1 u Sv/h ? 500mSv/h
Record personal dose history: a continuous every three minutes record 8 hours (dose rate 300mSv/h) more than
Response time: 0.5 seconds ? 30 seconds ? 10, according to be automatic adjustment, (dose rate > 6.8 dose rate mSv/h, 0.5 seconds response)
Power supply: AA1.5 V (5) battery section. Also available AA3.6 V battery section
> 400h continuous working hours: (1.5 V alkaline batteries)
Environmental temperature: - 30 ℃ ? 60 ℃
Humidity: 95% + 3% (40 ℃)
Size: 74 ? 20mm ? 50
Weight: 90g